#1 Home Improvement Retailer

Internet # 202844936

Model # QO200TRNM

Store SKU # 1001309200

QO 60 Amp 240-Volt 7.5 kW Non-Fuse AC Disconnect

$22.41
  • Square D AC disconnect for residential/commercial/industrial
  • Easily disconnect power to A/C equipment
  • Non-metallic, rainproof outdoor enclosure included
  • View More Details
Store
0 in stock
icon
Free & Easy Returns In Store or Online
Return this item within 90 days of purchase. Read Return Policy

Product Details

About This Product

The Square D by Schneider Electric QO 60 Amp 240-Volt 7.5 kW Non-Fused Air Conditioner Disconnect is UL listed for residential, commercial and industrial power distribution. QO AC disconnects are the "World's Finest" and designed with industry leading features for flexible application. The QO200TRNM features a non-metallic, rainproof enclosure designed for outdoor installations.

Highlights

  • Use to disconnect power to air conditioner equipment
  • Non-metallic, rainproof outdoor enclosure
  • Single-phase, 2-wire, 60 Amp, 240 VAC
  • Meets UL and ANSI safety requirements
  • Return Policy
  • California residents
     see Prop 65 WARNINGS

Product Information

Internet # 202844936

Model # QO200TRNM

Store SKU # 1001309200

Specifications

Dimensions: H 9.5 in, W 6.5 in, D 4.1 in

Dimensions

Product Depth (in.)

4.1 in

Product Height (in.)

9.5 in

Product Width (in.)

6.5 in

Details

Electrical Product Type

Disconnect

Fuse Type

Non-Fusible

Fused

Non-Fused

Indoor/Outdoor

Outdoor

Maximum Amperage (A)

60

Maximum Wattage (W)

7500 W

NEMA Configuration

NEMA 3R

NEMA Configuration Receptacle

No Receptacle

Phase Type

1 Phase

Power Distribution Features

No Additional Features

Product Weight (lb.)

1.91 lb

Returnable

90-Day

Type

Air Conditioner

Voltage (V)

240

Warranty / Certifications

Certifications and Listings

ANSI Certified, UL Listed

Manufacturer Warranty

90 Days. Please call 1-800-432-2599 for further information.

Questions & Answers

14Questions
caret
Q:Re: Square D QO200TRNM A/C Disconnect: There are six (6) slits on the back of the box. Can these be closed/caulked to prevent water from getting into the box? What are these for - Ventillation? MUST they remain open?
by|May 13, 2023
1 Answer
Answer This Question

A:  Hi, This QO200TRNM is NEMA 3R from factory. NEMA 3R enclosures are typically used in outdoor applications for wiring and junction boxes. This style of enclosure provides protection against falling rain, sleet, snow, and external ice formation. Indoors they protect against dripping water. This style of enclosure does not have a gasketed sealing surface. Some models have hasps for padlocking. Regards, Schneider Electric Customer Care

by|May 15, 2023
    caret
    Q:Can a second ground bar be ordered for use as a neutral bar when the installation is GFI?
    by|Feb 21, 2020
    2 Answers
    Answer This Question

    A:  No. This is a 240V single phase disconnect switch. The main purpose of the switch is to disconnect power only. It is not a Circuit Breaker or used for any other purpose other than disconnecting power - you'll void manufacturer warranty and make the switch non code compliant if you add anything to the disconnect. Recommend you having a CB that is GFCI. Your Neutral can pass through this disconnect from the breaker box to final location if your using a 4 wire 240V system. Use the Grounding bar for grounding only. You'll need to ground it to be code compliant.

    by|Jun 30, 2023
    1 found this answer helpful

    A:  Hello Ed, Unfortunately you can not use a GFI breaker in this enclosure, That would void UL and warranty. You can look at the QOE250GFINM. Regards, Schneider Electric Customer Care.

    by|Feb 27, 2020
      caret
      Q:Can this be used for an outside spa (hot tub) sub panel that requires a 60 amp 240 volt circuit?
      by|Mar 6, 2019
      2 Answers
      Answer This Question

      A:  You will need to verify with your Spa company manual the electrical requirements. Typically they require a GFI breaker. Square D does NOT offer a 2-pole, 60amp, GFI branch breaker, therefore a 60amp version of the Spa-Pak would NOT be available. The 60A does not have a load neutral connection. Regards, Customer Care

      by|Nov 20, 2019
        1 found this answer helpful

        A:  Physically, yes it can handle a 220v 60 amp disconnect requirement. However, you must check your NEC and local codes for any SPA-specific requirements; for example, this if not GFI protected.

        by|Nov 20, 2019
          1 found this answer helpful
          caret
          Q:I need to replace square d 60Mp ac disconnect but model number is different than the one currently installed
          by|Feb 17, 2019
          1 Answer
          Answer This Question

          A:  Yes, ALL of the Fusible and Non-Fusible Pullout type AC Disconnects have been obsolete since 2008. There are NO direct replacements, but for devices that can be used for AC Disconnect applications see the current Enclosed Molded Case Switches or Enclosed Circuit Breaker Devices QO200TRNM can be used but will require overcurrent protection upstream as it is a molded case switch and does not offer OCP. Regards, Customer Care

          by|Apr 2, 2020
            1 found this answer helpful
            Showing 1-4 of 14

            Customer Reviews

            4.7 out of 5

            • 4.7 out of 14 reviews
            • 100% recommend this product
            Filter by:
            Showing 1-10 of 14 reviews
            by
              Was just as described. Worked just as planned....
              Was just as described. Worked just as planned.
              by
              • Verified Purchase
              Rating provided by a verified purchaser...
              Rating provided by a verified purchaser
              by
              • Verified Purchase
              great price good quality...
              great price good quality
              by
              • Verified Purchase
              by
              • Verified Purchase
              by
              • Verified Purchase
              This device is serving very well as my swimming pool...
              This device is serving very well as my swimming pool heat pump's local disconnect switch. My contractor installed and wired it with no hitches.
              by
              • Verified Purchase
              Poorly made Square D used to be great but alas...
              Poorly made Square D used to be great but alas they have given to greed and not Quality. the are out for me.
              by
              Response from SchneiderCustomerCareJul 24, 2020
              Hello,
              We apologize for any inconvenience you might have encountered with our products. Let me assure you that our products are continually being improved based on user feedback. We would like to know more about your concern, please contact us anytime using our chat live https://www.se.com/us/en/work/support/customer-care/contact-schneider-electric.jsp where an agent will be able to give you further assistance on this matter.
              Warm regards.
              Schneider Electric Customer Care SquareD
              • Verified Purchase
              Easy to setup disconnect switch. It's all plastic. Used...
              Easy to setup disconnect switch. It's all plastic. Used this disconnect with a 9000 BTU Minisplit AC unit with 12 AWG wire THNN wire. Only improvement I could recommend is having 1/2" knockouts on both the bottom right and bottom left. Bottom Left only had 3/4" to 1" knockout. It has side 1/2".
              by
              • Verified Purchase
              1 found this review helpful
              Nice package
              Nice package
              by
              • Verified Purchase
              • Recommended
              Showing 1-10 of 14 reviews

              Compare Similar Items

              current item

              Fused

              Non-Fused

              Non-Fused

              Fused

              Type

              Air Conditioner

              Air Conditioner

              Air Conditioner

              NEMA Configuration

              NEMA 3R

              NEMA 3R

              NEMA 3R

              Electrical Product Type

              Disconnect

              Disconnect

              Disconnect

              Maximum Wattage (W)

              7500 W

              7400 W

              0 W